Can't Find the
Standard Length
from Big Brands?

We design and assemble to your exact blueprints -- non-standard lengths, hybrid connector configurations, specialized jacket chemistries. No minimum order. Samples in 3-5 business days.

Any Length · 0.3m+ Hybrid End Configs PVC / PUR / TPU Jacket CE · TÜV · cRUus · RoHS IP67 / IP68 Rated

3-5d

Sample Turnaround

NoMOQ

1 Piece Minimum

ISO9001

Audited Partners

Every Variable.
Engineered to Spec.

Where Phoenix Contact and Binder stop at catalog SKUs, we begin. Submit a drawing -- we'll match it exactly.

Cable Jacket Material Selection

PVC Economy Grade

PVC Jacket

Cost-effective standard jacket for general indoor automation. Excellent electrical insulation and flexibility at ambient temperatures. Ideal for light-duty sensor wiring in dry environments.

  • Operating range: −20°C to +80°C
  • Flame-retardant per UL 94 V-0
  • Suitable for dry / semi-dry environments
  • Lowest unit cost option
PUR EU Industrial Standard

PUR Jacket -- Oil & Chemical Resistant

Polyurethane outer jacket engineered for machine tool environments. Resists cutting fluids, hydraulic oils, and industrial solvents. The European standard for factory automation -- equivalent to IGUS chainflex® outer jacket chemistry.

  • Operating range: −40°C to +90°C
  • Oil-resistant per DIN EN 60811-404
  • Abrasion and notch-cut resistant
  • Halogen-free variants available
TPU Robotics Grade

High-Flex TPU -- Continuous Motion

Thermoplastic polyurethane jacket rated for 5,000,000+ flex cycles in continuous-motion robotic arms and cable carriers. Maintains flexibility at sub-zero temperatures without cracking.

  • 5M+ flex cycles rated
  • Operating range: −50°C to +105°C
  • Minimum bend radius: 5× OD
  • Designed for e-chain / drag chain use

Hybrid & Cross-Over Connector Configurations

SUPPORTED CONFIGURATIONS -- MIX & MATCH BOTH ENDS

CONFIG 01

M12 X-Code ↔ Industrial Shielded RJ45

The standard Profinet/EtherCAT field-to-switch assembly. Metal-body M12 X-Code on the device end, industrial-grade shielded RJ45 (IP20 or IP67 rated) on the cabinet end. Equivalent to Phoenix Contact VS-M12MSMK-RJ45S series.

CONFIG 02

M12 A-Code ↔ Strip & Tin (Bare Leads)

Sensor cable with a molded M12 connector on one end and stripped, tinned bare wire leads on the other -- ready for direct terminal block or PCB connection. Custom wire gauge, strip length, and tin depth to your wiring diagram.

CONFIG 03

M12 D-Code ↔ M12 X-Code (Cross-Protocol)

Cross-coding adapter cable for legacy Profibus-to-Profinet migration projects. We verify pin mapping against your application schematic before assembly to prevent field wiring errors.

CONFIG 04

7/8″ Power ↔ M12 A-Code (Hybrid Power+Signal)

Combined power and signal harness for fieldbus-powered devices. 7/8″ 5-pin on the supply end, M12 A-Code 5-pin on the device end. Rated up to 16A / 630V AC. Equivalent to Turck RSM-RKM hybrid series.

CONFIG 05

M8 B-Code ↔ Open-End with Ferrule Terminals

Compact M8 sensor cable with crimped ferrule terminals on the open end for DIN rail terminal block installation. Custom ferrule size, insulation color coding, and labeling per your cabinet layout drawing.

CUSTOM

Your Configuration -- Upload Your Drawing

Not listed above? We handle fully bespoke configurations. Upload your wiring definition diagram, IPC/WHMA-A-620 assembly drawing, or even a hand sketch -- our engineers will review and quote within 4 business hours.

FROM YOUR DRAWING TO DELIVERY -- 5 STEPS

01

Submit RFQ

Fill the form below. Attach drawing or spec sheet.

02

Engineering Review

We verify pin mapping, jacket spec, and compliance requirements.

03

Quote in 4h

Detailed quotation with full certification documentation.

04

Sample in 3-5 Days

Physical sample shipped from Suzhou/Wuxi manufacturing cluster.

05

Production Run

Approve sample → scale to full batch. No MOQ restrictions.

Send Us
Your Drawing.
We Build It.

Our engineering team responds within 4 business hours. The more detail you provide -- connector types, length, environment -- the faster we can return an accurate, fully certified quotation.

What to Include in Your RFQ

  • Connector type on both ends (e.g. M12 X-Code male / shielded RJ45)

  • Required cable length and quantity (prototype or production volume)

  • Application environment (indoor / oil exposure / continuous flex / outdoor)

  • Wiring diagram, IPC drawing, or specification sheet (optional but recommended)

Email: inquiry@conneclink.com

Response: Within 4 business hours (Mon-Fri, UTC+8)

CUSTOM CABLE ASSEMBLY RFQ

Cable Configuration

Specify exact length. Non-standard lengths are our specialty.

Application Environment (select all that apply)
Certifications Required (select all that apply)
Submitting your RFQ -- please wait...

Your technical data is treated with strict confidentiality. No spam. No data sharing. We quote -- you decide.

TIANLUN Custom Cable Assemblies · Built to Your Blueprint.

© 2025 Tianlun · conneclink.com · Suzhou / Wuxi, China · Serving NA & EU Markets